Med Phys ; 51(4): 2967-2974, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38456557

RESUMO

BACKGROUND: Position verification and motion monitoring are critical for safe and precise radiotherapy (RT). Existing approaches to these tasks based on visible light or x-ray are suboptimal either because they cannot penetrate obstructions to the patient's skin or introduce additional radiation exposure. The low-cost mmWave radar is an ideal solution for these tasks as it can monitor patient position and motion continuously throughout the treatment delivery. PURPOSE: To develop and validate frequency-modulated continuous wave (FMCW) mmWave radars for position verification and motion tracking during RT delivery. METHODS: A 77 GHz FMCW mmWave module was used in this study. Chirp Z Transform-based (CZT) algorithm was developed to process the intermediate frequency (IF) signals. Absolute distances to flat Solid Water slabs and human shape phantoms were measured. The accuracy of absolute distance and relative displacement were evaluated. RESULTS: Without obstruction, mmWave based on the CZT algorithm was able to detect absolute distance within 1 mm for a Solid Water slab that simulated the reflectivity of the human body. Through obstructive materials, the mmWave device was able to detect absolute distance within 5 mm in the worst case and within 3.5 mm in most cases. The CZT algorithm significantly improved the accuracy of absolute distance measurement compared with Fast Fourier Transform (FFT) algorithm and was able to achieve submillimeter displacement accuracy with and without obstructions. The surface-to-skin distance (SSD) measurement accuracy was within 8 mm in the anterior of the phantom. CONCLUSIONS: With the CZT signal processing algorithm, the mmWave radar is able to measure the absolute distance to a flat surface within 1 mm. But the absolute distance measurement to a human shape phantom is as large as 8 mm at some angles. Further improvement is necessary to improve the accuracy of SSD measurement to uneven surfaces by the mmWave radar.


Assuntos
Processamento de Sinais Assistido por Computador , Água , Humanos , Movimento (Física) , Radiografia
2.
Med Dosim ; 49(1): 30-36, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38087750

RESUMO

Mevion's single-room HYPERSCAN proton therapy system employs a proton multileaf collimator called the adaptive aperture (AA), which collimates individual spots in the proton delivery as determined by the Treatment Planning System (TPS). The purpose of this study is to assess the dosimetric benefits of the AA, specifically in the dynamic aperture (DA) mode, and evaluate its impact on proton treatment plan quality as compared to a traditional pencil beam scanning (PBS) system (Varian ProBeam). The spot dose distributions with dynamic collimation (DA), a unique AA shape for each energy layer, and with static collimation (SA), a single AA collimation shape shared by all energy layers per field, were calculated and compared with the spot dose distribution of the Varian ProBeam proton therapy system. The lateral and distal dose falloff gradients and their dependence on air gap were evaluated quantitatively. Treatment plans for ten arbitrarily selected intracranial target image sets were created, and the HYPERSCAN and ProBeam beam models were compared. The spot sizes of the HYPERSCAN system are significantly larger than ProBeam system, especially at low energy. With the help of DA, the lateral dose penumbra of the HYPERSCAN is dramatically improved at lower energy and comparable at higher to ProBeam PBS beams. While the ProBeam spot size does not change with the air gap, beam penumbra of the HYPERSCAN with DA increases with the air gap. The distal dose falloff gradient for the HYPERSCAN with or without DA remains consistently around 4.8 mm through all energies due to the beamline design, not substantially varying with energy or air gap. Treatment plans of ten randomly selected intracranial cases demonstrated favorable OAR sparing but unfavorable dose uniformity for the HYPERSCAN with DA compared to ProBeam. Dose shaping by adaptive aperture substantially improves the lateral penumbra without a significant change in the distal dose gradient. The dose gradients of the multiple beam DA plans with layer-by-layer blocking are improved compared with SA plans and are close to the ProBeam plans for the ten randomly selected brain cases. With layer-by-layer DA blocking, the HYPERSCAN plans have similar plan conformality indices as the ProBeam plans, but the overall plan quality indices are lower than ProBeam plans, largely due to the lower dose homogeneity. In some cases, DA blocking was found to be superior in sparing OAR surrounding the target.


Assuntos
Terapia com Prótons , Planejamento da Radioterapia Assistida por Computador , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Prótons , Terapia com Prótons/métodos , Etoposídeo
3.
Sci Rep ; 13(1): 20181, 2023 11 17.
Artigo em Inglês | MEDLINE | ID: mdl-37978269

RESUMO

Ultra-high dose rate (UHDR) radiotherapy (RT) or FLASH-RT can potentially reduce normal tissue toxicity. A small animal irradiator that can deliver FLASH-RT treatments similar to clinical RT treatments is needed for pre-clinical studies of FLASH-RT. We designed and simulated a novel small animal FLASH irradiator (SAFI) based on distributed x-ray source technology. The SAFI system comprises a distributed x-ray source with 51 focal spots equally distributed on a 20 cm diameter ring, which are used for both FLASH-RT and onboard micro-CT imaging. Monte Carlo simulation was performed to estimate the dosimetric characteristics of the SAFI treatment beams. The maximum dose rate, which is limited by the power density of the tungsten target, was estimated based on finite-element analysis (FEA). The maximum DC electron beam current density is 2.6 mA/mm2, limited by the tungsten target's linear focal spot power density. At 160 kVp, 51 focal spots, each with a dimension of [Formula: see text] mm2 and 10° anode angle, can produce up to 120 Gy/s maximum DC irradiation at the center of a cylindrical water phantom. We further demonstrate forward and inverse FLASH-RT planning, as well as inverse-geometry micro-CT with circular source array imaging via numerical simulations.


Assuntos
Radiometria , Tungstênio , Animais , Raios X , Doses de Radiação , Microtomografia por Raio-X , Imagens de Fantasmas , Dosagem Radioterapêutica , Método de Monte Carlo